Wireless Sensors

Real-Time Insight for Critical Environments

A wide range of parameters covering comprehensive monitoring needs. Engineered for accuracy and reliability with built-in memory for offline buffering. Ideal for laboratories, cleanrooms, manufacturing facilities, transportation and more.

Wireless Sensors, Real-Time Insight for Critical Environments

Our Sensor Types

A Sensor for Every Critical Parameter

Temperature Sensor, Monitoring -40°C to +85°C

Temperature

Monitoring -40°C to +85°C

Typical Use
  • Vaccine/Blood Storage
  • Refrigerators
  • Stability Chambers
  • Freezers
  • Incubators
  • Temperature mapping
  • Transportation monitoring
Specification
  • Measurement Range: -40 to +85°C / -40 to +185°F
  • Accuracy: ± 0.25°C / ± 0.45°F (see accuracy table page 3)
  • Measurement Resolution: 0.05°C / 0.09°F
  • Temperature Drift: 0.04°C / 0.072°F per year (max)
  • Battery Life: Up to 15 Years
  • Sensor Size: 19x19x3.5mm / 0.75x0.75x0.14 in
  • Data backfill: Up to 1 month
Humidity sensor, Monitoring 0 – 100% RH

Humidity

Monitoring 0 – 100% RH

Typical Use
  • Plant Growth Rooms
  • Cell Culture Incubators
  • Powder Processing
  • Cleanrooms
  • Dry Chemical Storage
  • Ambient lab humidity
Specification
  • Humidity Range: 0 to 100%RH
  • Recommended Operating Range: 20 – 80% RH
  • Humidity Accuracy: ±2% (0 to 90%RH) at 25°C / 77°F
  • Measurement Resolution: 0.01% RH
  • Long-term drift: Typical: <0.2% RH per year
  • Temperature Range: -40°C to 85°C / -40°F to 185°F
  • Temperature Accuracy: ±0.3°C / ±0.54 °F (Typical less than ±0.2°C (0.36°F))
  • Measurement Resolution: 0.01°C / 0.18°F
  • Long-term drift: Typical: <0.03°C / 0.054°F per year
  • Battery Life: Up to 15 Years
  • Sensor Size: 39x23x12 mm / 1.54x0.91x0.47 in
  • Data backfill: Up to 1 month
PT 100 / PT 1000, Monitoring temperature frin -200°C to +650°C

PT 100 / PT 1000

Monitoring -200°C to +650°C

Typical Use
  • Cryogenic Tanks
  • Autoclaves
  • ULT / -80 Freezers
  • Freeze-Dryers
  • Ovens
Specification
  • Measurement Range: -200 to +650°C / -328 to +1202°F
  • Accuracy: ± 0.2°C / ± 0.36°F
  • Measurement Resolution: 0.001°C
  • Temperature Drift: According to probe specification
  • Battery Type: 2 x AA
  • Battery Life: Up to 15 Years
  • Sensor Size: 95x66x25 mm / 3.74x2.60x0.98 in
  • PT100 Probes examples:
    • Low temperature (-90 to +250°C)
    • Cryogenic temperature (-196 to +100)
Water Detection sensor, Wet / Dry

Water Detection

Wet / Dry

Typical Use
  • Critical equipment
  • Server rooms
  • Cleanroom floors
  • Water purification
  • Safety showers
Specification
  • Sensor output: Present / Not-present
  • Responsiveness: Instant detection
  • Battery Life: Up to 15 Years
  • Operating conditions:
    • Temperature: -40°C to 85°C (-40°F to 185°F)
    • Humidity: 0 to 100% RH (non condensing)
    • Sensor Size: 19x19x2.5mm / 0.75x0.75x0.1 in
Access Detection sensor, Open / Closed and Duration

Access Detection

Open / Closed and Duration

Typical Use
  • Cold Storage Doors
  • Medicinal Cabinets
  • Fume Hood Sashes
  • Facility access monitoring
Specification
  • Sensor output: Open / Closed
  • Responsiveness: Instant detection
  • Detection range: Up to 30 mm
  • Battery Life: Up to 15 Years
  • Sensor Size: 39 x 23 x 12 mm / 1.54 x 0.91 x 0.47 in
  • Magnet Size: 25.5 x 10 x 9.5 mm / 1.00 x 0.39 x 0.37 in
Touch Sensor, trigger based notification

Touch

Trigger Based Notification

Typical Use
  • Inventory Replenishment
  • Service Requests
  • Waste Pickup Notification
  • Task Completion Logging
Specification
  • Sensor output: Touch
  • Measurement Interval: Trigger based
  • Battery Life: Up to 15 Years
  • Sensor Size: 26 x 26 x 5.9 mm / 1.02 x 1.02 x 0.23 inches
Proximity Sensor, Present / Not-present

Proximity

Present / Not-present

Typical Use
  • Asset removal
  • Sample removal
  • Access detection
  • Emergency kit monitoring
Specification
  • Sensor output: Present / Not-present
  • Responsiveness: Instant detection
  • Detection distance: 5 mm / 0.2 in
  • Battery Life: Up to 15 Years
  • Sensor Size: 19x19x2.5mm / 0.75x0.75x0.1 in
Indoor Climate sensor, CO2 / Temperature / Humidity / Barometric Pressure

Indoor Climate

CO2 / Temperature / Humidity / Barometric Pressure

Typical Use
  • Offices & write-up areas
  • Meeting rooms
  • Ventilation performance
  • Support ventilation adjustments
  • Workplace comfort
Specification
  • Carbon Dioxide
  • Measurement Range: 400 to 5000 ppm
  • Accuracy: ± 30 ppm, +3% of reading
  • Technology: Non Dispersive Infrared (NDIR)
  • Temperature
  • Measurement Range: 0 to +50°C / 32 to +120°F
  • Accuracy: ± 1°C / ± 1.8°F
  • Humidity
  • Measurement range: 10 to 95% RH
  • Accuracy: ± 3%
  • Barometric Pressure
  • Measurement range: 500 to 1110 hPa (mbar)
  • Accuracy: ± 1hPa (mbar)
  • Battery Type: 2 x AA
  • Battery Life: Up to 10 Years
  • Sensor Size: 95 x 66 x 25mm / 3,74 x 2,60 x 0,98 in

We Combine Sensors and Software

A Complete Platform for Environmental Monitoring

Empower your team with advanced visualization tools, real-time reporting, and intuitive dashboards. Get audit-ready documentation in just a few clicks. From simple temperature monitoring to complete smart lab solutions.

Purpose-built with the industry, for the industry.

Built for the Reality of Modern Laboratories

No operational disruption

Install the system while your facility remains fully operational.

Easy Retrofit

Expand monitoring coverage without complex technical interventions.

One Unified Data Source

Combine quality, operations, and HSE data in a single platform.

Improved Efficiency

Accelerate investigations and reduce deviations.

Sustainable Operations

Reduce travel, service visits, and energy consumption.

Predictive Insights

Use historical data to enable proactive corrective and preventive actions.

Metinor Emblem logo

Take Control of Your Sensors

Whether you operate laboratories, cleanrooms, or production environments, our platform provides the clarity and reliability you need to stay compliant and efficient.